Advancements in optical imaging have transformed biological analysis, allowing researchers to probe cellular structures and molecular interactions with increasing precision. Among these techniques, Stimulated Raman Scattering (SRS) microscopy provides label-free chemical contrast with high sensitivity and speed, making it particularly useful for studying live cells, tissues, and disease mechanisms at the molecular level.
To fully utilize SRS in biological applications, understanding its physical principles, instrumentation, and signal processing methods is essential. Optimizing excitation fields and distinguishing specific chemical bonds improve accuracy, while real-time tissue analysis with SRS offers new possibilities for medical diagnostics and surgical guidance.
Stimulated Raman Scattering (SRS) is a nonlinear optical process that enhances weak vibrational signals, enabling highly sensitive chemical imaging. Unlike spontaneous Raman scattering, which relies on the low probability of inelastic photon scattering, SRS amplifies the Raman response using two synchronized laser beams: a pump beam and a Stokes beam. When the frequency difference between these beams matches a molecular vibrational frequency, energy transfers from the pump to the Stokes beam, increasing the Stokes intensity (stimulated Raman gain) and decreasing the pump intensity (stimulated Raman loss). This amplification significantly boosts signal strength, making SRS far more efficient than spontaneous Raman techniques.
The efficiency of SRS depends on laser power, pulse duration, and molecular concentration. High-intensity laser pulses enhance stimulated scattering but can cause photodamage or nonlinear artifacts. Picosecond pulses offer a balance between spectral resolution and signal strength. The molecular concentration of the target species also affects signal strength, making SRS particularly effective for detecting lipids, proteins, and other biomolecules with distinct vibrational signatures.
A key advantage of SRS is its background-free nature, avoiding fluorescence interference common in spontaneous Raman measurements. Because SRS is a coherent process, only molecules resonant with the frequency difference between the pump and Stokes beams contribute to the signal, allowing precise chemical imaging without fluorescent labels. Additionally, the signal scales linearly with molecular concentration, unlike Coherent Anti-Stokes Raman Scattering (CARS), which can suffer from nonresonant background signals.
Implementing SRS microscopy requires a carefully designed nonlinear optical setup for high sensitivity and chemical specificity. The core components are two synchronized laser sources—a pump beam and a Stokes beam—whose frequency difference matches a molecular vibrational mode. Precise temporal and spectral overlap between these beams maximizes the SRS signal while minimizing background noise. Ultrafast laser sources, such as picosecond mode-locked lasers, provide the necessary spectral resolution and peak intensity for efficient nonlinear excitation.
Laser parameters significantly influence SRS performance. Picosecond pulses, typically 1–10 ps, balance spectral resolution and signal strength, preventing excessive spectral broadening while maintaining adequate peak power. Femtosecond pulses, though capable of higher peak intensities, can introduce spectral distortions reducing chemical specificity. Laser power must be controlled to prevent photodamage, with live cell imaging typically using power levels below 50 mW per beam to minimize cellular stress.
Beam synchronization and modulation improve weak SRS signal detection. A common approach modulates the Stokes beam at high frequencies (10–20 MHz), with lock-in amplification isolating the stimulated Raman gain or loss signal from laser fluctuations and noise. Electro-optic or acousto-optic modulators ensure precise modulation.
Focusing optics and detection schemes refine imaging performance. High-numerical-aperture (NA) objective lenses, often above 1.0 NA, tightly focus the excitation beams, enhancing light-sample interaction. The detection system, typically a photodiode or photomultiplier tube, captures the stimulated Raman loss signal in the forward direction, where the signal is strongest. Backward detection is used for thick or turbid samples but results in weaker signals due to scattering losses.
Extracting meaningful data from SRS microscopy requires precise detection and signal processing to distinguish weak vibrational signatures from background noise. Since SRS detects small changes in laser intensity—often 10⁻⁴ to 10⁻⁶ of the total beam power—highly sensitive photodetectors are essential. Silicon photodiodes and photomultiplier tubes (PMTs) are commonly used, with PMTs offering superior sensitivity. Avalanche photodiodes (APDs) provide fast response times and high quantum efficiency.
To enhance detection sensitivity, modulation and demodulation techniques are employed. Lock-in amplification is widely used, modulating the Stokes beam at high frequencies (10–20 MHz) and isolating the modulated signal to reject low-frequency noise from laser power drift or sample scattering. By tuning the lock-in amplifier to the modulation frequency, signal-to-noise ratios exceeding 1000:1 are achieved, allowing detection of subtle molecular variations.
Beyond hardware-based noise suppression, computational methods refine signal extraction. Fourier-transform filtering removes residual background fluctuations, while machine learning algorithms enhance chemical specificity. Deep learning models improve the identification of biomolecular distributions in heterogeneous tissues, and spectral unmixing techniques, such as principal component analysis (PCA) and independent component analysis (ICA), separate mixed chemical signals, resolving multiple biomolecular species within a single field of view.
Optimizing excitation fields in SRS microscopy enhances signal strength, contrast, and resolution. Beam focusing, pulse duration, and polarization control influence efficiency. High-numerical-aperture (NA) objective lenses, typically exceeding 1.0 NA, tightly focus the pump and Stokes beams, maximizing overlap with target molecules. This improves spatial resolution and increases excitation intensity, necessary for nonlinear optical processes while avoiding photodamage.
Temporal shaping of pulses further optimizes excitation. Picosecond pulses provide high spectral resolution, but pulse duration and spectral bandwidth must be balanced. Shorter pulses increase peak intensities but can introduce spectral broadening, reducing chemical specificity. Dispersion compensation techniques, such as pre-chirping pulses, maintain optimal characteristics throughout the optical path, ensuring well-defined vibrational resonance conditions and cleaner Raman spectra.
Enhancing the specificity of SRS imaging requires discriminating between different chemical bonds in biological samples. Each molecular bond exhibits a unique vibrational frequency, and tuning the frequency difference between the pump and Stokes beams selectively excites specific functional groups. This enables visualization of biomolecules such as lipids, proteins, and nucleic acids without fluorescent labels. Resolving closely spaced Raman peaks improves chemical composition mapping, particularly in complex cellular environments with overlapping biomolecular signals.
Hyperspectral SRS imaging captures a wide range of vibrational frequencies, constructing detailed spectral profiles for each pixel. Acquiring images at multiple Raman shifts differentiates structurally similar compounds. Computational techniques, such as spectral deconvolution and machine learning-based classification, enhance the ability to distinguish overlapping signals. These methods are particularly valuable in biomedical applications, where identifying subtle biochemical differences—such as distinguishing saturated from unsaturated lipids or differentiating protein secondary structures—provides insights into cellular metabolism and disease progression.
SRS microscopy enables real-time tissue analysis, offering rapid, label-free diagnostics for medical and surgical applications. Its high-speed imaging capability visualizes biochemical composition in living tissues, aiding in identifying pathological changes without conventional staining or histological preparation. In surgical oncology, real-time SRS imaging helps distinguish healthy from cancerous tissue, ensuring complete tumor resection while preserving surrounding structures.
Clinical applications demonstrate SRS’s potential in detecting malignancies based on unique molecular signatures. Studies show lipid-rich myelin structures in brain tissue exhibit distinct Raman shifts from tumor cells, allowing neurosurgeons to delineate tumor margins with high precision. In dermatology, SRS imaging aids in noninvasive skin cancer detection, differentiating malignant lesions from benign tissues based on protein and lipid content. As fiber-based SRS endoscopy advances, real-time in vivo imaging could become integral to diagnostics, providing immediate feedback during medical procedures.