What Is PI Percentage in an Oximeter?

A pulse oximeter is a small, non-invasive device used to measure oxygen saturation and pulse rate. Many modern oximeters also display the Perfusion Index (PI).

What is Perfusion Index (PI)?

Perfusion Index (PI) is a numerical value reflecting the strength of pulsatile (changing) blood flow at the measurement site. It is displayed as a percentage, representing the ratio of pulsatile blood flow to non-pulsatile (static) blood flow in peripheral tissue. This value is derived from the photoplethysmography (PPG) signal, which measures how light absorption changes as blood moves through arteries.

The PPG signal has two components: an alternating current (AC) component, which reflects arterial blood flow, and a direct current (DC) component, which represents static tissues and baseline blood volume. PI is calculated by dividing the AC component by the DC component and multiplying by 100 to express it as a percentage. PI indicates how well blood reaches the extremities, serving as a measure of peripheral perfusion.

What Your PI Reading Means

Perfusion Index values generally range from 0.02% to 20%. A higher PI value typically indicates stronger pulsatile blood flow and good peripheral perfusion. For instance, a PI above 1% usually signifies robust blood flow, which helps ensure accurate oxygen saturation and pulse rate readings.

Conversely, a lower PI value might suggest weaker pulsatile blood flow and potentially poor perfusion. Values below 0.3% to 0.4% can indicate poor peripheral circulation, and oximeter readings may be unreliable or unavailable. Healthcare professionals often use PI to assess oximeter signal quality and a patient’s peripheral circulation. However, PI is just one piece of information and should be considered alongside oxygen saturation and pulse rate for a comprehensive assessment.

Influences on PI Readings

Several factors can affect a PI reading. Cold extremities, for example, can cause blood vessels to constrict, reducing blood flow and leading to a lower PI. Movement of the patient or the sensor can also interfere with the oximeter’s signal, decreasing the PI.

Improper probe placement, where the sensor is not correctly fitted or aligned, can weaken the detected signal and result in a lower PI. Certain medical conditions, such as peripheral artery disease, diabetes, obesity, or blood clots, can also lead to poor perfusion and lower PI values. Medications that cause vasoconstriction (narrowing of blood vessels) or vasodilation (widening of blood vessels) can directly influence blood flow and, consequently, the PI reading. External pressure from tight clothing or jewelry on the measurement site can also impede blood flow, affecting the PI reading.