How Many Volts Does a Defibrillator Put Out?

Defibrillators are life-saving medical devices designed to treat sudden cardiac arrest, a condition where the heart abruptly stops pumping blood effectively. These devices function by delivering a controlled electrical shock to the heart, aiming to restore a normal rhythm. Understanding the electrical output is key to grasping how defibrillators operate.

Defibrillator Electrical Output

While voltage is involved in a defibrillator’s operation, the most important measurement for effective defibrillation is the energy delivered, measured in Joules. This energy represents the total electrical work done on the heart, encompassing voltage, current, and shock duration. This comprehensive measurement indicates the shock’s potential to reset the heart’s electrical activity.

A defibrillator can generate a significant voltage, often ranging from 1,000 to 5,000 volts, to overcome chest wall resistance and deliver the necessary current to the heart. For adults, typical energy settings for external defibrillation range from 120 to 360 Joules, while pediatric patients require much lower energy levels, often starting at 2 Joules per kilogram of body weight. The emphasis on Joules highlights that a successful defibrillation depends on the total energy supplied, which accounts for the interplay between voltage, current, and the body’s impedance.

How Defibrillators Restore Heart Rhythm

The electrical shock delivered by a defibrillator works by simultaneously depolarizing many myocardial (heart muscle) cells. This controlled electrical discharge aims to halt the chaotic electrical activity that characterizes life-threatening arrhythmias like ventricular fibrillation or pulseless ventricular tachycardia. Ventricular fibrillation involves disorganized electrical impulses, causing the heart’s lower chambers to quiver ineffectively instead of pumping blood. Pulseless ventricular tachycardia is a rapid, but ineffective, electrical rhythm that also prevents the heart from pumping blood.

By momentarily stopping all electrical activity, the shock creates an opportunity for the heart’s natural pacemaker, the sinoatrial node, to regain control. This allows the heart to re-establish a normal, organized sinus rhythm. The goal is to synchronize the heart’s electrical impulses, enabling coordinated contractions that effectively pump blood throughout the body. This “reset” mechanism helps restore circulation and prevent damage from lack of blood flow.

Variations in Defibrillator Devices

Defibrillators vary in design and energy output based on their intended use and type. Manual external defibrillators, typically operated by trained medical professionals, allow for adjustable energy levels, enabling clinicians to select the precise Joule setting appropriate for the patient’s condition. These devices offer flexibility in treatment strategies.

Automated external defibrillators (AEDs), commonly found in public spaces and used by lay rescuers, automatically analyze the heart’s rhythm. They deliver a fixed energy shock or an escalating series of shocks based on pre-programmed algorithms. This automation simplifies their use, making them accessible for immediate intervention. Additionally, implantable cardioverter-defibrillators (ICDs) are small devices surgically placed inside a patient’s body, designed to detect and automatically correct dangerous arrhythmias with much lower energy shocks, typically ranging from 10 to 40 Joules, directly applied to the heart. The energy delivered is always tailored to the patient’s needs and the specific defibrillator type.