Antibody-dependent cellular cytotoxicity (ADCC) is a crucial immune mechanism where antibodies help immune cells recognize and eliminate target cells. It plays a significant role in infection control, cancer immunotherapy, and therapeutic antibody development. ADCC assays evaluate the effectiveness of monoclonal antibodies and other biologics designed to enhance immune responses.
Understanding these assays and selecting the right approach is essential for obtaining reliable results.
ADCC relies on the interaction between immune effector cells, target cells, and antibodies. Natural killer (NK) cells are the primary mediators, using their Fc gamma receptor III (FcγRIII, CD16) to bind the Fc region of immunoglobulin G (IgG) antibodies. This triggers intracellular signaling, leading to the release of cytotoxic granules containing perforin and granzymes, which induce apoptosis in the target cell.
IgG1 and IgG3 antibodies have the highest affinity for CD16, and their glycosylation patterns affect binding efficiency and ADCC potency. Therapeutic monoclonal antibodies like rituximab and trastuzumab are engineered to optimize Fc-mediated interactions, enhancing NK cell recruitment for tumor destruction. Modifications such as afucosylation improve CD16 binding affinity, increasing ADCC activity.
Beyond NK cells, macrophages, monocytes, and neutrophils also contribute under certain conditions. Macrophages engage in phagocytosis and release inflammatory cytokines. Neutrophils, primarily involved in bacterial defense, mediate ADCC through reactive oxygen species (ROS) production and antibody-dependent trogocytosis, where membrane fragments from target cells transfer to effector cells. These alternative pathways highlight the complexity of ADCC beyond NK cell-mediated cytotoxicity.
Once an antibody binds to a target cell, FcγRIII (CD16) on NK cells engages, triggering intracellular signaling. This activates phosphorylation of immunoreceptor tyrosine-based activation motifs (ITAMs) within CD3ζ and FcεRIγ adaptors, recruiting spleen tyrosine kinase (Syk) and zeta-chain-associated protein kinase 70 (ZAP-70). These amplify the activation signal, initiating pathways responsible for cytotoxic granule release.
NK cell activation reorganizes its cytoskeleton, directing lytic granules toward the immunological synapse. These granules contain perforin, which forms transmembrane pores, allowing granzymes to enter and trigger apoptosis. Granzyme B cleaves caspase-3 and other pro-apoptotic substrates, leading to DNA fragmentation and mitochondrial permeabilization, ensuring target cell death.
NK cells also induce apoptosis through death receptor signaling. Fas ligand (FasL) and tumor necrosis factor-related apoptosis-inducing ligand (TRAIL) interact with Fas (CD95) and TRAIL receptors (DR4/DR5) on target cells, recruiting adaptor proteins like Fas-associated death domain (FADD) to activate caspase-8. This extrinsic apoptotic pathway provides an alternative cytotoxic mechanism, particularly when target cells resist granzyme-mediated apoptosis.
Several techniques assess ADCC, each offering advantages in sensitivity, reproducibility, and ease of use. These methods measure target cell lysis by detecting intracellular component release or changes in cell viability.
The chromium-51 (⁵¹Cr) release assay is a widely used method for quantifying ADCC. Target cells are pre-labeled with radioactive ⁵¹Cr, which integrates into intracellular proteins. When effector cells lyse the targets, released ⁵¹Cr is measured using a gamma counter. The detected radioactivity correlates with target cell destruction.
This method provides high sensitivity and quantitative results but has drawbacks, including regulatory restrictions, disposal challenges, and health hazards. Spontaneous ⁵¹Cr leakage can introduce background noise, affecting accuracy. Despite these limitations, it remains a benchmark for validating newer, non-radioactive alternatives.
Flow cytometry-based assays offer a non-radioactive alternative with single-cell resolution. Target cells are stained with fluorescent dyes like carboxyfluorescein succinimidyl ester (CFSE) or PKH26, enabling identification. After co-incubation with effector cells and antibodies, viability is assessed using propidium iodide (PI) or 7-aminoactinomycin D (7-AAD), which stain dead cells.
By gating on labeled target populations, researchers determine the percentage of lysed cells with high precision. Flow cytometry also evaluates NK cell activation markers like CD107a, providing insights into effector cell function. While highly informative, this method requires specialized equipment and expertise, making it less accessible for routine testing.
Fluorometric ADCC assays use enzyme-based detection to measure target cell lysis. One approach labels target cells with calcein-AM, a membrane-permeable dye that fluoresces upon hydrolysis. When cells lyse, calcein is released, and fluorescence intensity is measured. Another method detects lactate dehydrogenase (LDH) in culture media following membrane disruption.
These assays offer safer, non-radioactive alternatives while maintaining sensitivity. However, background fluorescence from spontaneous dye leakage can affect accuracy. Some fluorometric assays incorporate time-resolved fluorescence resonance energy transfer (TR-FRET) or bioluminescent readouts to enhance specificity, making them suitable for high-throughput antibody screening.
A reliable ADCC assay requires careful optimization. The process begins with preparing target cells, selected based on antigen expression. These cells must be cultured under optimal conditions to maintain viability and antigen presence. Before co-incubation, target cells are labeled with a detection reagent—radioactive isotope, fluorescent dye, or enzymatic substrate—depending on the assay format.
Effector cells, typically peripheral blood mononuclear cells (PBMCs) or purified NK cells, are then isolated and assessed for functionality. Factors like donor variability, activation state, and Fc receptor polymorphisms influence ADCC efficiency, requiring standardized effector cell sources when possible.
Target and effector cells are co-incubated in a 96-well plate at an optimized effector-to-target (E:T) ratio. The test antibody is added at varying concentrations to evaluate dose-dependent effects. Controls, including wells with target cells alone (spontaneous release) and those treated with a lysis-inducing agent (maximum release), are included to calibrate results.
After the assay, data analysis determines the extent of ADCC. The primary metric is the percentage of target cell lysis, calculated by comparing experimental signals to spontaneous and maximum release controls. This normalization accounts for background variations, ensuring accurate antibody efficacy assessment.
In dose-response experiments, the half-maximal effective concentration (EC₅₀) helps compare antibodies, indicating potency. A lower EC₅₀ suggests higher ADCC activity at lower antibody concentrations, a key factor in therapeutic evaluation.
Beyond cytotoxicity, additional analyses provide deeper insights. Flow cytometry-based assays assess NK cell activation markers like CD107a, reflecting degranulation activity. Cytokine presence, such as interferon-gamma (IFN-γ) and tumor necrosis factor-alpha (TNF-α), indicates broader effector cell activation. These supplementary data points help evaluate engineered antibodies with modified Fc regions, clarifying whether enhanced ADCC results from improved Fc receptor binding or increased effector cell activation.
By integrating multiple readouts, researchers gain a comprehensive understanding of how an antibody modulates immune-mediated target cell destruction.